3- HazMat container storage facility ( N°3 )

20' to 40'fcl HazMat container storage in dedicated and secure installation

Maximum capacity in the initial phase :
576 TEUs

Availability: Initial Phase

triangle

Opening hours


From Monday to Friday: 6 am - 7.30 pm.

I. HAZARDOUS MATERIALS CATEGORIES ALLOWED:

> Flammable and corrosive: Class 3, class 4.1/4.2/4.3 and class 8
> Toxic gases (gases and liquids): Class 2.1/2.3, class 6.1.
> Low explosive Haz Mat, non-flammable gas, Various Haz Mat: Class 1.4, Class 2.2, Class 9.
> Oxidizing products and peroxides: Class 5.1 and 5.2.
2018 04 04 HORSE Plan reperage des cellules stockage MD

II. FACILITIES AND EQUIPMENT:

> Rail and road services

  • 2 tracks of 375 m long.
  • 1 one-way traffic lane for trucks.
  • The 2 railway tracks & the road lane are operated by a gantry crane moving on rails

> Gantry crane  with piggyback legs for handling swap  bodies

  • 41 tons lifting capacity.
  • Travel speed: 100 m / min longitudinally and 1000 m / min laterally
  • Lifting speed allowing 15 cycles / hour on 2 daily posts: 210 cycles / day.

> Storage cell from 36 to 54 TEU accepting ISO Tanks and dry containers 20, 23, 30, 40 feet.
> Only HazMat containers can be stored inside the HazMat container storage facility (no swap bodies)

III. SAFETY DEVICES:

> Non-covered storage integrated into a Seveso platform
> No ignition sources in the storage area.
> Independent cells accepting only complementary classes, separated by firewalls.
> Storage of flammable gases, flammable and toxic gases and non-flammable toxic products in separate cells, confined by a movable flap except during handling operations, under permanent control of their atmosphere
> Two empty containers per cell  for the automatic recovery of rainwater and any effluents resulting from leaks
> Control system measuring the explosive limits, toxicity and temperature level depending the cells
> Every cell has a fire detection device directly connected to the control room; depending on HazMat stored, the extinction is realized by high-expansion foam or deluge system and activation of water curtains in order to contain any vapors and fumes.

IV. RELATED SERVICES:

> Cleaning, repair, heating, temperature monitoring and regulation
> Handling outside opening hours
2018 04 04 ProjetHorse  phasage

OUR RANGE OF SERVICES



Comments are closed.

Horn Logisitic Services - Tous droits réservés 2013 - Crédits photo: Didier Carette - Plans et vue 3D Architopia - Mentions légales